Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | ||
model characteristic | SAMM-120-1H | |
Rated output voltage | DC +12V | BAT +13.8V |
Output interface location | The eight-digit P=9.5mm terminal with cover is marked with AC-L, AC-N, DC+, DC-; BAT-,BAT+,BATSW | |
Output voltage range | Tuning error: ±0.5V | Tuning error: ±0.6V; |
Rated input current | 10A | 0.5A |
Load current range | 0.5~10A ( MAX=10A ) | 0.2~0.5A ( MAX=0.5A ) |
Output voltage ripple | Vp-pmax<120 mV | Vp-pmax<138 mV |
Li ; Lo Adjustment rate | Line:±0.5%;Load:±0.5% | Line:±1%;Load:±15%(BAT±3%) |
Comprehensive voltage stabilization accuracy | ±1% | ±16%(BAT±4%) |
Rated output power | 120W | |
Rated working efficiency | ≥75% (output power is rated) | |
Rated input voltage | Operating voltage: AC176V-264V Rated voltage: AC220V Interface position: three-position socket with cover marked AC-L, AC-N, FG | |
Rated input current | Rated current: AC0.5A, current range AC0.5~1A | |
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | |
Input surge current | The impulse current of the power supply grid at the moment of working power-on: the maximum value of cold start is 60A/10mS | |
Output overload protection | The +12V overload protection point is about 105%~120% of the rated output power; The overload protection is in the mode of online current limiting and voltage reduction; Short-circuit protection requires the input to be reset | |
UPS battery management function | External battery (capacity 5~30AH) is required for backup power supply, the system will automatically convert to backup power supply when AC power supply stops, the system conversion ≤ 50mS, and automatically switch to AC power supply and battery management when AC power supply is normal (BAT+ and BAT.SW need to be shorted to enable UPS function) | |
It has the function of floating charging the external battery (5~30AH), and the battery has an undervoltage of 10V±0.6V for load discharge, and the short-circuit protection function can be automatically reset. | ||
Power time parameters | SETUP TIME: ≈ 200mS; RISE TIME: ≈50mS; THE HOLD UP TIME ≈ 20mS | |
Electrical strength parameters | Input-Output:>AC1.5KV;Input-Housing:>AC1.5KV;Output-Housing:>AC0.5KV Leakage Current<5mA 50Hz 1min. | |
Operating temperature parameters | The operating temperature drift coefficient is about ±0.03 [%/°C]; The absolute temperature rise coefficient is about 0.50 [°C/W]; When the working output is rated power, the absolute temperature rise of the body is 25°C±5°C | |
Environmental condition parameters | Storage environment: -20°C~+85°C; 10%~95%RH.。 Working environment: -10°C~+50°C; 20%~90%RH.。 (Varies depending on the usage environment and power) | |
Working heat dissipation method | Designed for continuous working mode, self-cooling to help heat dissipation (the difference in use environment and installation position affects power usage and service life) | |
Appearance installation dimensions | Size: L195×W110×H50mm3; Installation size: L188×W98mm2, L188×W23mm2 | |
Net weight and appearance | The total weight is about 850g; The bottom case is 1.5 mm thick aluminium with a silver sand-oxygen finish, and the cover case is 0.8 mm thick iron with a silver electroplastic finish | |
Certified safety specifications | National standard GB-4943 | |
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |
13760359528
Mailbox:2008_sunsheng@163.com
21887590@163.com
Address:Building 4,Block B,Fangxing Science
and Technology Park,No. 17 Baonan
Road,Nanlian Community,Longgang
Street,Longgang District,Shenzhen
Scan to learn more