Detailed description:
· Small size and light weight. · High reliability and low price. · The circuit has a wide input voltage range. · High conversion efficiency and low operating temperature rise. · Built-in filter circuit, less external radiation interference. · It has basic protection circuit and good adaptability to the environment. · 4 hours, 100% full load aging and full range of functional tests. | ||||
parameter model characteristic | SB2D-025-1HA | S050S200A4 | S050S300B7 | S240S100B0 |
Rated output voltage | DC 12V | DC5V | DC 5V | DC24V |
Output interface location | Positive inside and negative outside | |||
Output voltage range | ±10% | |||
Rated output current | Rated current: 2A | Rated current: 2A | Rated current: 3A | Rated current: 1A |
Load current range | Current range: 0-2.0A | Current range: 0-2.0A | Current range: 0-3.0A | Current range: 0-1.0A |
Output voltage ripple | Vp-pmax<100 mV | |||
Li ; Lo Adjustment rate | Line:±10%;Load:±10% | |||
Comprehensive voltage stabilization accuracy | ±10% | |||
Rated output power | 25W | 10W | 15W | 25W |
Rated working efficiency | Greater than 80% (output power is rated value) | |||
Rated input voltage | Rated voltage: AC100-240V | |||
Rated input current | Rated current: AC0.45A, current range AC0.2A~0.45A | |||
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | |||
Input surge current | The impact current on the power supply grid at the moment of power-on: the maximum value during cold start is 30A/10mS. | |||
Input voltage protection | …… | |||
Output overload protection | The overload protection point is about 120-200% of the rated output power; the overload protection is an online power limiting voltage reduction method; the short circuit protection is a hicup method | |||
Output overvoltage protection | …… | |||
Power time parameters | Setup time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20 mS | |||
Isolation voltage parameters | Input-output: AC3KV, leakage current <5mA 50Hz 1min. | |||
Operating temperature parameters | The operating temperature drift coefficient is approximately ±0.02[%/℃]; the absolute temperature rise coefficient is approximately 5.00[℃/W]; | |||
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) | |||
Working heat dissipation method | Continuous working mode, natural cooling and heat dissipation of the body | |||
Appearance installation dimensions | 97*44.5*28mm | |||
Net weight and appearance | Net weight 160, black | |||
Design standard basis | GB4943,GB9254,3C,UL, CE | |||
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |
13760359528
Mailbox:2008_sunsheng@163.com
21887590@163.com
Address:Building 4,Block B,Fangxing Science
and Technology Park,No. 17 Baonan
Road,Nanlian Community,Longgang
Street,Longgang District,Shenzhen
Scan to learn more