SACF-060-KH with charging and unlocking


Detailed description:

 Small size and light weight.

• High reliability and low price.

 The circuit has a wide input voltage range.

• High conversion efficiency and low operating temperature rise.

 Built-in filter circuit, less external radiation interference.

• It has basic protection circuit and good adaptability to the environment.

4 hours, 100% full load aging and full range of functional tests.

parameter

model

characteristic


SACF-060-KH

Rated output voltage

DC +15V

DC +12V

BAT +18.5V

Output interface location

The six-digit P=9.5mm terminal block is marked DC+12V, DC-; BAT+, BAT-

Output voltage range

Setting error: ±0.5V

Setting error: ±0.5V

Setting error: ±0.6V

Rated output current

2A

1A

0.5A

Load current range

0.5~2A ( MAX=2A )

0.5~1A ( MAX=1A )

0.2~0.5A ( MAX=0.5A )

Output voltage ripple

Vp-pmax<150 mV

Vp-pmax<120 mV

Vp-pmax<180 mV

Li ; Lo Adjustment rate

Line:±0.5%;

Load:±0.5%

Line:±0.5%;

Load:±0.5%

Line:±1%;

Load:±15%(BAT±3%)

Comprehensive voltage stabilization accuracy

±5%

±5%

±16%(BAT±4%)

Rated output power

67W

Rated working efficiency

≥70% (output power is rated value)

Rated input voltage

Operating voltage: AC176V-264V Rated voltage: AC220V Interface location: Three-position covered socket marked AC-L, AC-N, FG

Rated input current

Rated current: AC0.6A, current range AC0.2~1A

AC input frequency

Rated AC voltage frequency range 47~63Hz, sine wave

Input surge current

The impact current on the power supply grid at the moment of power-on: the maximum value during cold start is 60A/10mS.

Output overload protection

The overload protection point is about 120%~220% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is an online power limiting method

UPS battery management function

An external battery (capacity 3~6AH) is required for backup power supply. When the AC power supply is stopped, the system automatically switches to the backup power supply. The system conversion is ≤50mS. When the AC power supply is normal, it automatically switches to the AC power supply and manages the battery.

It has the function of float charging external batteries (3~6AH). The battery has an undervoltage of 10V±0.6V when the load is discharged. The short-circuit protection function can be automatically reset. The battery short-circuit protection needs to be restarted after backup.

Power time parameters

Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS

Electrical strength parameters

Input-output: >AC1.5KV; Input-casing: >AC1.5KV; Output-casing: >AC0.5KV Leakage current <5mA 50Hz 1min.

Operating temperature parameters

The working temperature drift coefficient is about ±0.03[%/℃]; the absolute temperature rise coefficient is about 0.50[℃/W]; when the working output is rated power, the absolute temperature rise of the body is 25℃±5℃

Environmental condition parameters

Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power)

Working heat dissipation method

Designed to work continuously, with self-cooling to assist heat dissipation. (Differences in usage environment and installation location affect power usage and lifespan)

Appearance installation dimensions

Specifications and dimensions: L130×W98×H37mm3; Installation dimensions: L52×W31mm2, L125×W0mm2

Net weight and appearance

The total weight is about 416g; the bottom shell is made of 1.2mm thick aluminum with a silver sand-oxygen surface treatment; the cover shell is 0.5mm thick iron with a silver electroplastic surface treatment.

Certified safety specifications

National standard GB-4943

Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around

2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively.

The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax.

3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value.


Next:SFPA-060-1B2023-06-29

Recently Viewed:

news.related_news

A powerful switching power supply manufacturer in the industry
24 Hours
Hotline

13760359528

Mailbox:2008_sunsheng@163.com

                21887590@163.com

Address:Building 4,Block B,Fangxing Science 

                 and Technology Park,No. 17 Baonan 

                 Road,Nanlian Community,Longgang 

                 Street,Longgang District,Shenzhen

Scan to learn more