Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 8 hours, 100% full load aging and full range of functional tests. | ||
parameter model characteristic | SKGB-200-1B | SKGB-200-1H |
Rated output voltage | DC 24V | DC 12V |
Output interface location | 9-position 9.5-M4 wiring port marked OUTPUT: V+; V- | |
Output voltage range | Setting error: <±3%; Adjustable range: ±15% | |
Rated output current | Rated value 9A, current range 0~10A | Rated value 12A, current range 0~17A |
Output voltage ripple | Vnor<50mV;Vp-p100Hz<120mV;Vp-pmax<240mV | |
Li ; Lo Adjustment rate | Line:±0.5%;Load:±0.5% | |
Comprehensive voltage stabilization accuracy | ±1% | |
Rated output power | 200W | |
Rated working efficiency | ≥85% (output power is rated value) | |
Rated input voltage | Rated voltage: AC110/220V±15%, operating voltage: AC110/220V±30%. Interface: 9-digit 9.5-M4 interface designation INPUT: AC-L, AC-N, FG | |
Rated input current | Rated current: AC220V: AC2.85A, current range AC0.1A~2.5A; (AC110V: AC4.85A, current range AC0.5A~5.5A) | |
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | |
Input surge current | The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 20A/10mS. | |
Input voltage protection | The output voltage exceeds 120% of the rated output voltage and the power supply enters the protection state. To recover, the input needs to be reset. | |
Input overvoltage protection | The overload protection point is about 120% of the rated output current, and the protection is a current limiting and voltage reduction method; the short circuit protection is an online voltage shutdown method, and the input needs to be reset to recover. | |
Working overheat protection | ------The overheat protection point is 85℃±5℃, and the protection mode is online shutdown mode. The whole machine can return to normal when the temperature is lower than 50±3℃ | |
Multi-machine serial and parallel function | Allows the same series of power supplies to be used in series and parallel with multiple machines (parallel machines do not share current) | |
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS | |
Isolation voltage parameters | [Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <8mA | |
Operating temperature parameters | The working temperature drift coefficient is about ±0.05[%/℃]; the absolute temperature rise coefficient is about 0.2[℃/W]; when the working output is the rated power, the absolute temperature rise of the body is 25℃±5℃ | |
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: 0℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) | |
Working heat dissipation method | Designed for continuous working mode, air cooling and heat dissipation (differences in usage environment and installation location affect power usage) | |
Appearance installation dimensions | Specifications and dimensions: L215×W116×H30mm32 | |
Net weight and appearance | The total weight is about 500g; the bottom shell is made of 1.5mm thick aluminum with a white polished and oxidized surface treatment; the cover shell is made of 0.8mm thick iron with a white nickel-plated surface treatment. | |
Design standard basis | National standard GB-4943; GB-9254 | |
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |