Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | |
parameter model characteristic | SB3D-040-1BA |
Rated output voltage | DC +24.0V |
Output interface location | The output is 18#AWG1C+1, 5.5*2.1 tone cable, inner positive and outer negative, cable length 1.5 m |
The output voltage | Setting error: ±2% |
Rated output current | Rated current: 1.8A Load current range: 0~1.8A |
Output voltage ripple | Vp-p100Hz<60mV;Vp-pmax<150 mV |
Li ; Lo Adjustment rate | Line:±0.5%;Load:±2.0% |
Comprehensive voltage stabilization accuracy | ±3% |
Rated output power | 43.2W |
Rated working efficiency | ≥75% (output power is rated value) |
Rated input voltage | Input voltage range: AC85-265V. Interface location: standard three-pin input socket |
Rated input current | Rated current: AC0.43A, current range AC0.35A~1.2A |
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave |
Input surge current | The impact current on the power supply grid at the moment of power-on: the maximum value during cold start is 30A/10mS. |
Input overvoltage protection | The input allowable range is AC0~280V; the overvoltage protection point is AC300V±5V, and the power supply enters a non-restorable shutdown state. |
Output overload protection | The overload protection point is about 150-250% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is an online power limiting method |
Multi-machine serial and parallel function | --------- |
Power time parameters | Setup time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20 mS |
Isolation voltage parameters | Input-output: AC 1.5 KV, input-chassis: AC 1.5 KV Leakage current <5mA 50Hz 1min. |
Operating temperature parameters | The working temperature drift coefficient is about ±0.03[%/℃]; the absolute temperature rise coefficient is about 0.7[℃/W]; when the working output is rated power, the absolute temperature rise of the body is 25℃±5℃ |
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) |
Working heat dissipation method | Continuous working mode, natural cooling and heat dissipation of the body |
Appearance installation dimensions | Appearance size: L116XW47XH32mm3, placed on the desktop |
Net weight and appearance | About 250g, plastic case, black |
Design standard basis | GB4943,GB9254,3C,UL |
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |