Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | |||
parameter model characteristic | SKJA-080-3CFA | ||
Rated output voltage | DC1:+5V | DC2:+15V | DC3:-15V |
Output interface location | Nine-position 8.5-M4 wiring port marked OUTPUT: DC3; DC2+; COM; COM; DC1+; DC2+ | ||
Output voltage range | Setting error: <±3%; Adjustable range: ±10% | Setting error: <±5%; | Setting error: <±5%; |
Rated output current | Rated value 5A, current range 0~5A | Rated value 2A, current usage range 0~2A | Rated value 2A, current usage range 0~2A |
Output voltage ripple | Vnor<20mV;Vp-p100Hz<50mV;Vp-pmax<80mV | Vnor<80mV;Vp-p100Hz<150mV;Vp-pmax<200mV | Vnor<80mV;Vp-p100Hz<150mV;Vp-pmax<200mV |
Li ; Lo Adjustment rate | Line:±0.5%;Load:±0.5% | ||
Comprehensive voltage stabilization accuracy | ±3% | ||
Rated output power | 80W | ||
Rated working efficiency | ≥75% (output power is rated value) | ||
Rated input voltage | Rated voltage: AC220±15%, operating voltage: AC220±30%. Interface: Nine-digit 9.5-M4 interface marking INPUT: AC-L, AC-N, FG | ||
Rated input current | Rated current: AC220V: AC0.85A, current range AC0.6A~1A | ||
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | ||
Input surge current | The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 20A/10mS. | ||
Input voltage protection | The input allowable range is AC0~280V; the overvoltage protection point is AC300V±5V, and the power supply enters a non-restorable shutdown state. | ||
Output overload protection | The overload protection point is about 110% of the rated output current, and the protection is a current limiting and voltage reduction method; the short circuit protection is an online voltage shutdown method, and the input needs to be reset to recover. | ||
Working overheat protection | ------The overheat protection point is 85℃±5℃, and the protection mode is online shutdown mode. The whole machine can return to normal when the temperature is lower than 50±3℃ | ||
Multi-machine serial and parallel function | Allows the same series of power supplies to be used in series and parallel with multiple machines (parallel machines do not share current) | ||
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS | ||
Isolation voltage parameters | [Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <8mA | ||
Operating temperature parameters | The working temperature drift coefficient is about ±0.05[%/℃]; the absolute temperature rise coefficient is about 0.2[℃/W]; when the working output is the rated power, the absolute temperature rise of the body is 25℃±5℃ | ||
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: 0℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) | ||
Working heat dissipation method | Designed for continuous working mode, natural cooling and heat dissipation (differences in usage environment and installation location affect power usage) | ||
Appearance installation dimensions | Specifications and dimensions: L159×W98×H47mm3; Maximum size: L160×W100×H48mm3; Installation dimensions: L150×W85mm2, L149×W10mm2 | ||
Net weight and appearance | The total weight is about 500g; the bottom shell is made of 1.5mm thick aluminum, with a polished and oxidized surface treatment and bright color; the cover shell is 0.6mm thick iron, with a nickel-plated surface treatment and bright color | ||
Design standard basis | National standard GB-4943; GB-9254 | ||
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |