Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 8 hours, 100% full load aging and full range of functional tests. | |
parameter model characteristic | ST6B-250-1B |
Rated output voltage | DC 24V |
Output interface location | The seven-digit 9.5-M4 wiring port is marked OUTPUT: DC+; DC- |
Output voltage range | Setting error: <±2%; Adjustable range: ±11% |
Rated output current | Rated value 10A, current range 0~11A |
Output voltage ripple | Vnor<100mV;Vp-p100Hz<150mV;Vp-pmax<240mV |
Li ; Lo Adjustment rate | Line:±0.5%;Load:±0.5% |
Comprehensive voltage stabilization accuracy | ±3% |
Rated output power | 240W |
Rated working efficiency | ≥80% (output power is rated value) |
Rated input voltage | Rated voltage: AC220/110V±15%, operating voltage: AC220/110V±30%. Interface location: seven-digit 10.0-M4 interface marked AC-L, AC-N, FG |
Rated input current | Rated current: AC220V: AC1.2A, current range AC1.0A~2.5A; (AC110V: AC2.5A, current range AC1.0A~2.6A) |
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave |
Input surge current | The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 60A/10mS. |
Input voltage protection | Undervoltage protection point AC150V±5V, the power supply enters a restorable (reset input) shutdown state; overvoltage protection point AC300V±5V, the power supply enters a non-restorable shutdown state |
Output overload protection | The overload protection point is about 105% of the rated output current, and the protection is current limiting and voltage reduction. |
Output undervoltage protection | -------------------- |
Working overheat protection | Overheating protection is when the shell temperature is higher than about 85±3℃, and the protection is in the online voltage shutdown mode; automatic recovery is when the shell temperature is lower than about 65±3℃ |
Multi-machine serial and parallel function | Allows the same series of power supplies to be used in series with multiple machines |
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS |
Isolation voltage parameters | [Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <5mA |
Operating temperature parameters | The working temperature drift coefficient is about ±0.03[%/℃]; the absolute temperature rise coefficient is about 0.16[℃/W]; when the working output is the rated power, the absolute temperature rise of the body is 25℃±5℃ |
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) |
Working heat dissipation method | Designed for continuous working mode, fan cooling and heat dissipation (differences in usage environment and installation location affect power usage) |
Appearance installation dimensions | Specifications and dimensions: L200×W99×H40mm3; Maximum size: L210×W100×H42mm3; Installation dimensions: L120×W80mm2, L157×W18mm2 |
Net weight and appearance | The total weight is about 800g; the bottom shell is made of 2.0mm thick aluminum with natural color surface treatment; the cover shell is 0.8mm thick iron with natural color electroplating surface treatment |
Design standard basis | National standard GB-4943; GB-9254 |
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |