Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | ||||
parameter model characteristic | SACF-060-1H | SACF-060-1K03 | SACF-060-1I02 | SACF-060-1B+ |
Rated output voltage | DC +12V BAT +13.8V | DC +15V BAT +18.5V | DC +18V BAT +21.5V | DC +24V BAT +27.6V |
Output interface location | The six-digit P=9.5mm terminal block is marked DC+12V, DC-; BAT+, BAT- | |||
Rated output current | 5A 0.5A | 3.5A 0.5A | 3.5A 0.5A | 2.5A 0.5A |
Load current range | 0~5A ( MAX=5A ) 0~0.5A ( MAX=0.5A ) | 0~3.5A ( MAX=3.5A ) 0~0.5A ( MAX=0.5A ) | 0~3.5A ( MAX=3.5A ) 0~0.5A ( MAX=0.5A ) | 0~2.5A ( MAX=2.5A ) 0~0.5A ( MAX=0.5A ) |
Output voltage ripple | Vp-pmax<120 mV Vp-pmax<200mV | |||
Li ; Lo Adjustment rate | Line:±0.5%;Load:±3% Line:±1%;Load:±15% | |||
Comprehensive voltage stabilization accuracy | ±5% ±20% | |||
Rated output power | 60W | |||
Rated working efficiency | ≥70% (output power is rated value) | |||
Rated input voltage | Operating voltage: AC176V-264V Rated voltage: AC220V Interface location: Three-position covered socket marked AC-L, AC-N, FG | |||
Rated input current | Rated current: AC0.6A, current range AC0.2~1.0Ab | |||
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | |||
Input surge current | The impact current on the power supply grid at the moment of power-on: the maximum value during cold start is 60A/10mS. | |||
Output overload protection | The overload protection point is about 120%~220% of the rated output power; the overload protection is an online power limiting and voltage reduction method; the short circuit protection is an online power limiting method | |||
UPS battery management function | An external battery (capacity 3~6AH) is required for backup power supply. When the AC power supply is stopped, the system automatically switches to the backup power supply. The system conversion is ≤50mS. When the AC power supply is normal, it automatically switches to the AC power supply and manages the battery. | |||
It has the function of float charging external batteries (3~6AH). The battery has an undervoltage of 10V±0.6V when the load is discharged. The short-circuit protection function can be automatically reset. The battery short-circuit protection needs to be restarted after backup. | ||||
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS | |||
Electrical strength parameters | Input-output: >AC1.5KV; Input-casing: >AC1.5KV; Output-casing: >AC0.5KV Leakage current <5mA 50Hz 1min. | |||
Operating temperature parameters | The working temperature drift coefficient is about ±0.03[%/℃]; the absolute temperature rise coefficient is about 0.50[℃/W]; when the working output is rated power, the absolute temperature rise of the body is 25℃±5℃ | |||
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) | |||
Working heat dissipation method | Designed to work continuously, with self-cooling to assist heat dissipation. (Differences in usage environment and installation location affect power usage and lifespan) | |||
Appearance installation dimensions | Specifications and dimensions: L130×W98×H37mm3; Installation dimensions: L52×W31mm2, L125×W0mm2 | |||
Net weight and appearance | The total weight is about 416g; the bottom shell is made of 1.2mm thick aluminum with a silver sand-oxygen surface treatment; the cover shell is 0.5mm thick iron with a silver electroplastic surface treatment. | |||
Certified safety specifications | National standard GB-4943 | |||
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |
13760359528
Mailbox:2008_sunsheng@163.com
21887590@163.com
Address:Building 4,Block B,Fangxing Science
and Technology Park,No. 17 Baonan
Road,Nanlian Community,Longgang
Street,Longgang District,Shenzhen
Scan to learn more