Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | |||
parameter model characteristic | SK4B-500-1B | SK4B-500-1H | SK4B-500-1C |
Rated output voltage | DC24V | DC12V | DC48V |
Output interface location | The seven-digit 9.5-M4 wiring port is marked OUTPUT: DC+; DC- | ||
Output voltage range | Setting error: <±1%; Adjustable range: ±10% | ||
Rated output current | 0~22A | 0~42A | 0~12A |
Output voltage ripple | Vnor<20mV ;Vp-p100Hz<100mVp-p;Vp-pmax<200mVp-p | ||
Li ; LoAdjustment rate | Line:±0.5%;Load:±0.5% | ||
Comprehensive voltage stabilization accuracy | ±3% | ||
Rated output power | ≈500W | ||
Rated working efficiency | ≈80% | ||
Rated input voltage | Rated voltage: AC220/110V±15%, operating voltage: AC220/110V±30%. Interface location: seven-digit 9.5-M4 interface marked AC-L, AC-N, FG | ||
Rated input current | Rated current: AC220V: AC2.5A, current range AC2.2A~3.5A; | ||
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave | ||
Input surge current | The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 55A/10mS. | ||
Input overvoltage protection | The overload protection point is about 108% of the rated output current, and the protection is a current limiting and voltage reduction method; the short circuit protection is an online voltage shutdown method, and the input needs to be reset to recover. | ||
Output undervoltage protection | The undervoltage protection point is about 10% of the rated output voltage. The protection is an online voltage shutdown mode. The input needs to be reset to recover. | ||
Working overheat protection | Overheating protection is when the shell temperature is higher than about 85±3℃, and the protection is in the online voltage shutdown mode; automatic recovery is when the shell temperature is lower than about 65±3℃ | ||
Multi-machine serial and parallel function | The same series of power supplies are allowed to be used in series with multiple machines, but current sharing is not allowed. | ||
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS | ||
Isolation voltage parameters | [Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <5mA | ||
Operating temperature parameters | The working temperature drift coefficient is about ±0.05[%/℃]; the absolute temperature rise coefficient is about 0.13±10%[℃/W]; when the working output is rated power, the absolute temperature rise of the body is 35℃±5℃ | ||
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+40℃; 20%~90%RH. (Varies depending on usage environment and power) | ||
Working heat dissipation method | Designed for continuous working mode, air cooling and heat dissipation (differences in usage environment and installation location affect power usage) | ||
Appearance installation dimensions | Maximum size: L280×W120×H50mm3; | ||
Net weight and appearance | The total weight is about 1700g; the bottom shell is made of 2.0mm thick aluminum, and the polished surface is silver and bright; the cover is 0.8mm thick iron, and the nickel-plated surface is silver and bright | ||
Design standard basis | National standard GB-4943; GB-9254 | ||
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |
13760359528
Mailbox:2008_sunsheng@163.com
21887590@163.com
Address:Building 4,Block B,Fangxing Science
and Technology Park,No. 17 Baonan
Road,Nanlian Community,Longgang
Street,Longgang District,Shenzhen
Scan to learn more