Detailed description:
• Small size and light weight. • High reliability and low price. • The circuit has a wide input voltage range. • High conversion efficiency and low operating temperature rise. • Built-in filter circuit, less external radiation interference. • It has basic protection circuit and good adaptability to the environment. • 4 hours, 100% full load aging and full range of functional tests. | |
parameter model characteristic | STEA-180-1B |
Rated output voltage | Seven-digit 9.5-7P wiring port marked OUTPUT: GND, GND, +24V, +24V |
Output interface location | DC:+24V |
Output voltage range | Setting error<±5% |
Rated output current | Rated current 7.8A range 0---7.5A |
Output voltage ripple | Vnor<100mv Vp_p100Hz<80mv VP-Pmax<240mv |
Li ; Lo Adjustment rate | Line: ±0.5%, Load: ±3% |
Comprehensive voltage stabilization accuracy | ±5% |
Rated output power | 180W |
Rated working efficiency | ≈80% |
Rated input voltage | Rated voltage: AC220V±15%, operating voltage: AC220V±30%. Interface position: seven-position 9.5-7 position wiring port label INPUT: AC-L, AC-N, FG |
Rated input current | Rated current: AC1.0A, current range AC0.6A~1.5A |
AC input frequency | Rated AC voltage frequency range 47~63Hz, sine wave |
Input surge current | The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 20A/10mS. |
Input voltage protection | Rated civilian voltage 220V±15% interface location |
Output overload protection | The overload protection point is about 120% of the rated output current, and the protection is a current limiting and voltage reduction method; the short circuit protection is an online voltage shutdown method, and the input needs to be reset to recover. |
Output undervoltage protection | The undervoltage protection point is approximately AC150V±5V, and the power supply enters a restorable (reset input) shutdown state. The overvoltage protection point is AC300V±5V, and the power supply enters a non-restorable shutdown state. |
Working overheat protection | The overheat protection point is 85℃±5℃, and the protection mode is online shutdown. The whole machine can return to normal when the temperature is lower than 50±3℃ |
Multi-machine serial and parallel function | Allows the same series of power supplies to be used in series with multiple machines |
Power time parameters | Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS |
Isolation voltage parameters | [Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <5mA |
Operating temperature parameters | The working temperature drift coefficient is about ±0.03[%/℃]; the absolute temperature rise coefficient is about 0.3[℃/W]; when the working output is the rated power, the absolute temperature rise of the body is 25℃±5℃ |
Environmental condition parameters | Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: -10℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power) |
Working heat dissipation method | Designed for continuous working mode, natural cooling and heat dissipation (differences in usage environment and installation location affect power usage) |
Appearance installation dimensions | Specifications and dimensions: L159×W98×H47mm3; Maximum size: L160×W100×H48mm3; Installation dimensions: L150×W85(33)mm2, L149×W10mm2 |
Net weight and appearance | The total weight is about 500g; the bottom shell is made of 2mm thick aluminum with black oxidized surface treatment; the cover shell is 0.8mm thick iron with black electroplastic surface treatment |
Design standard basis | National standard GB-4943; GB-9254 |
Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around 2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively. The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax. 3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value. |