SKFD-200-3HK

SKFD-200-3HK

  • Category:Laser power
  • Browse number:
  • QR code:
  • Release time:2023-08-17 10:45:28
  • Product description

SKFD-200-3HK



Detailed description:

• Small size and light weight.

• High reliability and low price.

• The circuit has a wide input voltage range.

• High conversion efficiency and low operating temperature rise.

• Built-in filter circuit, less external radiation interference.

• It has basic protection circuit and good adaptability to the environment.

• 8 hours, 100% full load aging and full range of functional tests.

parameter

model

characteristic

SKFD-200-3HK

Rated output voltage

DC1( +12V)      DC2(+15V)      DC3(-15V)

Output interface location

7-position 9.5-M4 wiring port marked OUTPUT: DC3-, DC2+, COM, DC1+,

Output voltage range

Setting error: <±3%; Adjustable range: ±10%

Rated output current

Rating DC1(10A) DC2+(2A) DC3-(2A)

Output voltage ripple

 Vp-pmax<150mV

Li ; Lo Adjustment rate

Line:±0.5%;Load:±0.5%

Comprehensive voltage stabilization accuracy

DC1±5% DC2 DC3±10%

Rated output power

200W

Rated working efficiency

≥78% (output power is rated value)

Rated input voltage

Rated voltage: 100-240VAC, operating voltage: AC90-264 V Interface: 7-digit 9.5-M4 interface marking INPUT: AC-L, AC-N, FG

Rated input current

Rated current: AC220V: AC0.85A, current range AC0.6A~0.95A

AC input frequency

Rated AC voltage frequency range 47~63Hz, sine wave

Input surge current

The impact surge current on the power supply grid at the moment of power-on: the maximum value during cold start is 20A/10mS.

Input voltage protection

The input allowable range is AC0~280V; the overvoltage protection point is AC300V±5V, and the power supply enters a non-restorable shutdown state.

Output overload protection

The overload protection point is about 110% of the rated output current, and the protection is a power limiting voltage reduction method; the short circuit protection is an online voltage drop method, which can automatically resume work.

Working overheat protection

------The overheat protection point is 85℃±5℃, and the protection mode is online shutdown mode. The whole machine can return to normal when the temperature is lower than 50±3℃

Multi-machine serial and parallel function

Allows the same series of power supplies to be used in series and parallel with multiple machines (parallel machines do not share current)

Power time parameters

Preparation time (SETUP TIME) ≈ 200mS; Stability time (RISE TIME) ≈ 50mS; Holding time (HOLD UP TIME) ≈ 20mS

Isolation voltage parameters

[Input-output: AC1.5KV, input-casing: AC1.5KV, output-casing: AC0.5KV] 50Hz power on for 1min: leakage current <8mA

Operating temperature parameters

The working temperature drift coefficient is about ±0.05[%/℃]; the absolute temperature rise coefficient is about 0.2[℃/W]; when the working output is the rated power, the absolute temperature rise of the body is 25℃±5℃

Environmental condition parameters

Storage environment: -20℃~+85℃; 10%~95%RH. Working environment: 0℃~+50℃; 20%~90%RH. (Varies depending on usage environment and power)

Working heat dissipation method

Designed for continuous working mode, natural cooling and heat dissipation (differences in usage environment and installation location affect power usage)

Appearance installation dimensions

Specifications and dimensions: L159×W98×H38mm3; Maximum size: L160×W100×H38mm3; Installation dimensions: L150×W85mm2, L149×W10mm2

Net weight and appearance

The total weight is about 600g; the bottom case is made of 1.5mm thick aluminum with a polished and oxidized surface in white; the cover is made of 1mm thick aluminum with a polished and oxidized surface in white

Design standard basis

National standard GB-4943; GB-9254

Note: 1) The above detection indicators are measured under the following conditions: within the input rated voltage and output rated load range, the environment is 25℃, 85%RH. , when there is no wind around

2) Output DC voltage ripple detection: Use a parallel twisted wire with a length of 30cm and a cross-section of 1mm2 connected to one end of a 0.1μF and 0.47μF capacitor to bypass the detection point and detect 100Hz respectively.

 The maximum peak-to-peak value of the main frequency ripple is Vp-p100Hz and the maximum peak-to-peak value of the comprehensive ripple is Vp-pmax.

     3) Li voltage regulation rate: when the load is at the rated value, the input voltage changes within the rated range; Lo load regulation rate: when the input is at the rated voltage value, the load changes from zero to the rated value.




Previous:KX type 200W series2023-06-29
Next:STEA-180-1B2023-08-17

Recently Viewed:

news.related_news

A powerful switching power supply manufacturer in the industry
24 Hours
Hotline

13760359528

Mailbox:2008_sunsheng@163.com

                21887590@163.com

Address:Building 4,Block B,Fangxing Science 

                 and Technology Park,No. 17 Baonan 

                 Road,Nanlian Community,Longgang 

                 Street,Longgang District,Shenzhen

Scan to learn more